S., Yusup and N.D., Vinh and N., Mellon and A., Hassan (2007) Tube skin temperature prediction of catalytic reforming unit (CRU) heaters. WSEAS Transactions on Information Science and Applications, 4 (1). pp. 183-189. ISSN 17900832
paper.pdf
Restricted to Registered users only
Download (12kB)
Abstract
The maximum duty of reformer heaters is governed by the occurance of maximum tube skin temperature of the heaters. The value of maximum tube skin temperatures of the heaters must not exceed theirs' maximum allowable design temperature. The paper highlights the simulation of the tube skin temperatures of CRU heaters and temperature distribution across the heater tubes. The simulated results are important in order to access the heaters performance and prediction of the coke formation in tubes. The simulated results are verified using Plant data. The simulation is done using finite element approach. A two dimensional model is developed with a front view and a cross-sectional view for each heater. The maximum percentage deviation of predicted tube skin temperature using Finite element approach was found to be 1.2%.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Coking; Computer simulation; Finite element method; Mathematical models; Reforming reactions; Temperature distribution; Catalytic reforming unit; Coke formation; Tube furnaces; Tube skin temperature; Coke fueled furnaces |
Subjects: | T Technology > TP Chemical technology |
Departments / MOR / COE: | Departments > Chemical Engineering |
Depositing User: | Assoc Prof Dr Suzana Yusup |
Date Deposited: | 09 Mar 2010 02:09 |
Last Modified: | 19 Jan 2017 08:27 |
URI: | http://scholars.utp.edu.my/id/eprint/590 |
Available Versions of this Item
- Tube skin temperature prediction of catalytic reforming unit (CRU) heaters. (deposited 09 Mar 2010 02:09) [Currently Displayed]