Thermal Field Study and Analysis in Hybrid Solar Flue Gas Chimney Power Plant

Aja, Ogboo Chikere and Al-Kayiem, Hussain H. and Abdul Karim, Z. A. (2011) Thermal Field Study and Analysis in Hybrid Solar Flue Gas Chimney Power Plant. In: National Postgraduate Conference 2011 (NPC 2011), 19-20 Sept 2011, Universiti Teknologi PETRONAS, Tronoh, Perak, MALAYSIA.

[thumbnail of Thermal_Field_Study_Aja.pdf] PDF
Thermal_Field_Study_Aja.pdf
Restricted to Registered users only

Download (239kB)

Abstract

The concept of using flue gas waste heat as a backup in a solar chimney power plant is driven by the objective of plant performance enhancement. This paper presents experimental results of thermal field of hybrid solar-flue-gas chimney power plant at different mode (solar mode, hybrid mode and flue gas mode). The experimental test rig consisted of two inclined absorber plate and diffuser surface with total area of 3.15 m2, flue gas channel (1m x 3m x 0.05m), greenhouse (air flow channel of 1m x 3m x 0.16m at inlet and 1m x 3m x 0.075m at exit), chimney of diameter 0.15m and height of 4m, flue gas inlet diffuser (1m x 0.3m x 0.05m) and flue-gas source (biomass burner coupled with centrifugal blower powered using a variable speed motor). The temperature distribution in the hybrid solar-flue gas chimney power plant test-rig was measured. Temperature difference between the chimney base (absorber plate exit air) and the ambient were studied which is the driving force in the setup. On solar mode, the driving force (temperature difference between the absorber plate exit air and the ambient air) gave a maximum ∆T of 27.6 oC at irradiance of 797 W/m2. With flue gas as thermal backup during the day, maximum ∆T reached 38.1oC for inlet flue-gas temperature of 101.6 oC and irradiance of 672 W/m2, with flue gas as the only source of thermal energy in the night, the temperature difference, ∆T, got up to 25.9 oC at a flue-gas inlet temperature of 107.6 oC. The sloar mode experiment carried out after night mode experiment shows that the ∆T of the system the next day enhanced as the temperature difference increased from sunrise contrary to the drop on normal day.

Item Type: Conference or Workshop Item (Paper)
Subjects: T Technology > TJ Mechanical engineering and machinery
Departments / MOR / COE: Departments > Mechanical Engineering
Depositing User: AP Dr Zainal Ambri Abdul Karim
Date Deposited: 05 Dec 2011 03:01
Last Modified: 19 Jan 2017 08:22
URI: http://scholars.utp.edu.my/id/eprint/6940

Actions (login required)

View Item
View Item